b5
Advanced solutions designed
To deliver consistent performance across mordern surgical procedures.

Advanced Bipolar

Our Advanced Bipolar System (DAVID BAP Generator) is a high-performance electrosurgical device purpose-built for precision soft tissue closure, coagulation, and cutting in complex surgical environments.
Availability:

Product Overview & Surgical Applications

Tailored for surgical facilities, healthcare institutions, medical device distributors, and acute care hospitals, this system delivers consistent, repeatable performance for both open and minimally invasive laparoscopic procedures. It is widely deployed in general surgery, thoracic surgery, gynecology, urology, and cardiothoracic operations, with a core capability to safely seal vessels up to 5mm in diameter, streamlining surgical workflows and reducing intraoperative complexity.

Key Features & Clinical Benefits

Precision Bipolar Output Performance

The integrated DAVID BAP Generator features a 5-inch capacitive touch display for intuitive, real-time operation, paired with floating output technology that delivers uniform energy delivery for consistent tissue coagulation and clean cutting. Its natural cooling system eliminates the need for external cooling accessories, reducing equipment bulk and minimizing intraoperative downtime, while maintaining stable performance even during prolonged surgical procedures.

Optimized Handpiece Design for Surgical Flexibility

The system offers a complete portfolio of manual control handpieces, including 5mm vessel sealer models and dedicated forceps vessel sealers, to adapt to varied surgical approaches. The ergonomic manual control design enables surgeons to adjust coagulation and cutting actions in real time, while the precision jaw structure minimizes thermal spread to surrounding healthy tissue, lowering postoperative complication risks and accelerating patient recovery.

Robust Environmental Adaptability

Engineered for global use across diverse clinical settings, the system supports stable operation in a temperature range of 5°C to 40°C, with an extended storage temperature range of -40°C to 60°C, making it suitable for facilities in varying climate zones. For units stored outside the standard operating temperature range, a 1-hour pre-conditioning period at 20°C±5°C ensures full functional integrity before use.

Full Technical Specifications

Advanced Bipolar

Operation

Transportation and storage

Ambient temperature range

5-40°C

-40-60°C

Relative humidity

≤80%

≤80%

Atmospheric pressure

860hpa - 1060hpa

860hpa - 1060hpa

Manual Control 5mm Vessel Sealer

Product Description

Specs & Model

Shaft Length mm

Shaft Diameter mm

Jaw Size mm

Coagulation Length mm

Cutting
Length mm

Manual Control 5mm Vessel Sealer

LS23

230

5

≥18

20.5

18.5

LS37

370

5

≥18

20.5

18.5

LS44

440

5

≥18

20.5

18.5

Manual Control Forceps Vessel Sealer

Product Description

Specification
& Model

Jaw Size mm

Coagulation Length mm

Cutting
Length mm

Manual Control Forceps Vessel Sealer

1201

≥18

22

20

Quality Compliance & Regulatory Certifications

Our soft tissue closure cutting system is manufactured in strict accordance with ISO 13485 international medical device quality management system standards. The product holds CE certification for the European medical device market, complies with FDA regulatory requirements for electrosurgical devices, and meets all relevant IEC 60601-1 safety standards for medical electrical equipment. All components undergo rigorous biocompatibility testing and sterile validation to ensure full compliance with global healthcare regulatory requirements.

FAQ

What is the maximum vessel size the Advanced Bipolar System can reliably seal?

The system is engineered to safely and effectively seal blood vessels with a maximum diameter of 5mm, meeting the core hemostasis requirements of most general and specialized surgical procedures.

What preparations are needed before using the system after long-term storage?

If the system is stored outside the standard operating temperature range (5°C to 40°C), it must be placed in an environment of 20°C±5°C for at least 1 hour before operation to ensure stable performance.

Can the system adapt to both open and laparoscopic surgeries?

Yes, the system offers multiple handpiece options with varying shaft lengths, including 230mm, 370mm, and 440mm models, to accommodate both open surgical procedures and minimally invasive laparoscopic operations.

What is the recommended storage environment for the system?

The system should be stored in a well-ventilated, non-corrosive environment with relative humidity ≤80%, and an ambient temperature within the -40°C to 60°C range to preserve component integrity.

Previous: 
Next: 

Quick Links

Products

Contact Us

  Phone     +86-574-87802005
  Email       info@nbverykind.com
  Address  No.100 Jinghua Rd, High-tech zone,              Ningbo 315040, Zhejiang Province, China
Copyright 2026 Ningbo Verykind Medical Device Co., Ltd. All Rights Reserved. Sitemap  Privacy Policy